Solves: Power outages in homes and shops
Roxon Hybrid 6.2 kW
6,200 W · 12,400 VA peak · 1 MPPT
6.2 kW48 VMPPT 60–500 VZero-export
View product →Illustrative image
Hybrid inverters
48 V zero-export hybrid inverters. Solar energy is used first, the surplus charges the battery and, if the power goes out, the battery takes the load in 10 ms. The grid stays as backup.
Solves: Power outages in homes and shops
6,200 W · 12,400 VA peak · 1 MPPT
6.2 kW48 VMPPT 60–500 VZero-export
View product →
Solves: Power outages in large homes and businesses
8,600 W · 2 MPPT · up to 9 in parallel
8.6 kW48 V2 MPPTParallelZero-export
View product →
Solves: Power outages in businesses and large loads
11,000 W · 2 MPPT · up to 9 in parallel
11 kW48 V2 MPPTParallelZero-export
View product →Panels, the grid and a generator can all supply the inverter. Solar energy is used first; the surplus charges the battery and the grid only comes in as backup. Nothing is exported to the grid. During an outage, the inverter switches to battery in 10 ms.
RO62: Roxon Hybrid 6.2 kW · RO86: Roxon Hybrid 8.6 kW · RO11: Roxon Hybrid 11 kW
| Parameter | RO62 | RO86 | RO11 |
|---|---|---|---|
| AC input | |||
| Input wiring | L + N + PE | ||
| Input voltage | 220 / 230 / 240; 90–280 ± 3 (normal) / 170–280 ± 3 (UPS) V | ||
| Frequency | 50 / 60 (adaptive) Hz | ||
| AC output | |||
| Rated power | 6,200 W | 8,600 W | 11,000 W |
| Output voltage | 220 / 230 / 240 ± 5 % V | ||
| Output frequency | 50 / 60 ± 0.1 % Hz | ||
| Waveform | Pure sine wave | ||
| Transfer time (adjustable) | 10 (computers) / 20 (appliances) ms | ||
| Peak power | 12,400 VA | 17,200 VA | 22,000 VA |
| Overload in battery mode | 11 s @ 105–150 %; 2 s @ 150–200 %; 400 ms @ > 200 % | ||
| Battery | |||
| Rated voltage | 48 V | ||
| Constant charge voltage | 56.4 V | ||
| Float voltage | 54 V | ||
| Solar charger | |||
| PV charging method | MPPT | 2 × MPPT | 2 × MPPT |
| Max. PV power | 6,200 W | 2 × 5,500 W | 2 × 5,500 W |
| MPPT range | 60–500 V | 90–500 V | 90–500 V |
| Max. PV voltage | 500 V | ||
| Max. PV charging current | 120 A | 150 A | 150 A |
| Max. AC charging current | 100 A | 120 A | 150 A |
| Max. total charging current | 120 A | 150 A | 150 A |
| Communication | |||
| Display | LCD (operating mode, load, input, output) | ||
| RS232 | 2,400 baud | ||
| Expansion slot | Lithium BMS communication card / WiFi / dry contact | ||
| Functions | |||
| Parallel connection | No | Yes | Yes |
| Max. units in parallel | Not applicable | 9 units | 9 units |
| Generator input | Yes, with dry-contact start | ||
| WiFi module | Optional: app monitoring and settings, automatic generator start | ||
| Protections | |||
| Output short circuit | Yes | ||
| Overload | Yes | ||
| Battery undervoltage | Yes | ||
| Battery reverse polarity | Yes | ||
| Environment | |||
| Operating temperature | −10 to 50 °C | ||
| Storage temperature | −15 to 60 °C | ||
| Altitude | ≤ 1,000 without derating; max. 4,000 (IEC 62040) m | ||
| Humidity | 20–95 (non-condensing) % | ||
| Noise | ≤ 50 dB | ||